WattPerchMenu

States

Maine

12 of 12 facts verified from the statuteChecked November 20, 2026

Where it stands

In force since July 29, 2026.

Checked November 20, 2026In force July 29, 2026

“The effective date for non-emergency legislation enacted in the Second Regular Session of the 132nd Legislature is Wednesday, July 29, 2026.”

Bill

LD 1730 (SP 676), An Act to Make Small Plug-in Solar Generation Devices Accessible for All Maine Residents...; Public Law chapter 644

Source: legislature.maine.gov, checked November 20, 2026

Signed
April 6, 2026
Takes effect
July 29, 2026 Chapter text has no emergency clause; digest lists LD 1730 as Public 644 without emergency note.
Session
2026 132nd Legislature, Second Regular Session; the official digest cites it as 'Public Law 2025, chapter 644'.

What the law says

Size limit

1,200 W

Up to 420 W AC per service address with no conditions; 421-1,200 W only if installed by a Maine-licensed electrician on a dedicated single-outlet circuit plus notice to utility.

“combined inverter output exceeding 420 watts, but no more than 1,200 watts, per service address”

Source: legislature.maine.gov, checked November 20, 2026

Utility approval and notice

No approval, interconnection application/agreement/study, fee or extra equipment; but notice to utility within 30 days required above 420 W

“shall provide a notification to the transmission and distribution utility ... within 30 days of installation”

Source: legislature.maine.gov, checked November 20, 2026

Renters, landlords and HOAs

Customer installing on a structure it does not own must not compromise the structure or violate codes and must restore it on removal; no landlord-consent or HOA rule

“on or in a structure the customer does not own shall ensure that the installation or operation does not compromise the integrity of the structure”

Landlords and associations, state by state

Source: legislature.maine.gov, checked November 20, 2026

Batteries

Plug-in battery systems count toward the same 420 W / 1,200 W combined caps

“plug-in photovoltaic systems and plug-in battery systems with combined inverter output exceeding 420 watts, but no more than 1,200 watts”

Source: legislature.maine.gov, checked November 20, 2026

Certification

UL 3700 (or other applicable UL/NEC standards), or comparable NRTL standard, or configured per adopted NEC

“Listed or certified in accordance with UL 3700, the Outline of Investigation for Interactive Plug-in Photovoltaic Equipment and Systems”

What the certifications mean, law by law

Source: legislature.maine.gov, checked November 20, 2026

Other rules

Utility not liable; inverters must shut off within 0.2 s on disruption; utility may not deny a compliant system

“A transmission and distribution utility is not liable for any damage or injury caused by the installation or operation of an eligible system”

Source: legislature.maine.gov, checked November 20, 2026

Kits and this limit

The size limit

Each kit’s inverter AC output is compared with Maine’s limits, the kit on its own: up to 420 W without conditions, up to 1,200 W with conditions. This checks size only. The law has other rules too, such as certification.

“combined inverter output exceeding 420 watts, but no more than 1,200 watts, per service address”

Within the size limit

Bright Saver Balcony Solar Kit, 180 W (one panel)

360 W of AC output is within the 420 W that Maine allows without conditions.

Bright Saver does not list Maine among the states it ships to.

Its values and price

Within the size limit

Bright Saver Balcony Solar Kit, 360 W (two panels)

360 W of AC output is within the 420 W that Maine allows without conditions.

Bright Saver does not list Maine among the states it ships to.

Its values and price

Within the limit, with conditions

CraftStrom 800 Watt | Plug&Play Solar

800 W of AC output is above 420 W, so Maine requires installation by a Maine-licensed electrician on a dedicated single-outlet circuit, and a notice to the utility within 30 days of installation.

Its values and price

Within the limit, with conditions

CraftStrom 800 Watt Eco-Line | Plug&Play Solar

800 W of AC output is above 420 W, so Maine requires installation by a Maine-licensed electrician on a dedicated single-outlet circuit, and a notice to the utility within 30 days of installation.

Its values and price

Within the limit, with conditions

US Solar Supplier 810W Plug In Solar Kit with APsystems EZ1 Microinverter and SunModo Racking

900 W of AC output is above 420 W, so Maine requires installation by a Maine-licensed electrician on a dedicated single-outlet circuit, and a notice to the utility within 30 days of installation.

Its values and price

Within the limit, with conditions

US Solar Supplier 1180W Plug-In Solar Kit with APsystems EZ1 Microinverter + HanerSun 590W Panels

900 W of AC output is above 420 W, so Maine requires installation by a Maine-licensed electrician on a dedicated single-outlet circuit, and a notice to the utility within 30 days of installation.

Its values and price

Within the limit, with conditions

Mango Power S 120V 1200W Plug-In Solar Kit with Zero-Export Gateway

1,120 W of AC output is above 420 W, so Maine requires installation by a Maine-licensed electrician on a dedicated single-outlet circuit, and a notice to the utility within 30 days of installation.

Its values and price

Within the limit, with conditions

CraftStrom 1200 Watt Eco-Line | Plug&Play Solar

1,200 W of AC output is above 420 W, so Maine requires installation by a Maine-licensed electrician on a dedicated single-outlet circuit, and a notice to the utility within 30 days of installation.

Its values and price

No size check

US Solar Supplier 880W Plug-In Solar Kit with Hoymiles Microinverters + Hanersun Panels

Its AC output is not verified, so we cannot compare it with the limit.

Its values and price

In order of inverter output, smallest first. We have not tested these kits. The calculator gives its output, savings and payback for your address. For a kit whose seller does not list Maine for shipping, it gives no payback.

General information, not legal advice. Your lease, your HOA and your utility can add rules of their own. Where a field says “not yet verified from the statute”, we have not filled it in from any other source.

Work out your numbers