Size limit
1,200 W
Per electric meter; only on systems using smart meters.
“maximum combined inverter capacity of not more than 1,200 watts”
Source: legislature.vermont.gov, checked November 20, 2026
Where it stands
In force since July 1, 2026.
“This act shall take effect on July 1, 2026.”
Bill
S.202 (Act 149), An act relating to plug-in photovoltaic devices
Source: legislature.vermont.gov, checked November 20, 2026
1,200 W
Per electric meter; only on systems using smart meters.
“maximum combined inverter capacity of not more than 1,200 watts”
Source: legislature.vermont.gov, checked November 20, 2026
No section 248 permit, no interconnection agreement, no PUC jurisdiction; no approval, installation fee or extra equipment; utility may recover overloading costs
“shall not be required to obtain an interconnection agreement with an electric distribution company”
Source: legislature.vermont.gov, checked November 20, 2026
Tenant gives landlord 10 days' notice; landlord may set reasonable restrictions within 10 days; deed restrictions/covenants may not prohibit; condo patio-railing exception does not apply to plug-in devices
“A tenant shall provide at least 10 days' notice to the landlord of the tenant's intent to install a plug-in photovoltaic device”
Landlords and associations, state by state
Source: legislature.vermont.gov, checked November 20, 2026
Excluded: not eligible for net metering and exports not compensated; net-metering customers may not also install one
“Generation exported to the grid by a plug-in photovoltaic device shall not be compensated by an electric distribution company.”
What unpaid power does to a kit’s savings
Source: legislature.vermont.gov, checked November 20, 2026
The statute we read says nothing on this.
Source: legislature.vermont.gov, checked November 20, 2026
UL 3700 (or equivalent NRTL certification) and IEEE 1547-2018 operation
“complies with UL 3700 for plug-in photovoltaic systems by UL Solutions or an equivalent certification”
What the certifications mean, law by law
Source: legislature.vermont.gov, checked November 20, 2026
Smart meter required; device must be securely attached; municipal bylaws may not regulate; utility liability not addressed
“Plug-in photovoltaic devices shall only be connected to systems using smart meters.”
Source: legislature.vermont.gov, checked November 20, 2026
The size limit
Each kit’s inverter AC output is compared with Vermont’s limit of 1,200 W, the kit on its own. This checks size only. The law has other rules too, such as certification.
“maximum combined inverter capacity of not more than 1,200 watts”
Within the size limit
360 W of AC output is within Vermont’s limit of 1,200 W.
Bright Saver does not list Vermont among the states it ships to.
Its values and priceWithin the size limit
360 W of AC output is within Vermont’s limit of 1,200 W.
Bright Saver does not list Vermont among the states it ships to.
Its values and priceWithin the size limit
800 W of AC output is within Vermont’s limit of 1,200 W.
Its values and priceWithin the size limit
800 W of AC output is within Vermont’s limit of 1,200 W.
Its values and priceWithin the size limit
900 W of AC output is within Vermont’s limit of 1,200 W.
Its values and priceWithin the size limit
900 W of AC output is within Vermont’s limit of 1,200 W.
Its values and priceWithin the size limit
1,120 W of AC output is within Vermont’s limit of 1,200 W.
Its values and priceWithin the size limit
1,200 W of AC output is within Vermont’s limit of 1,200 W.
Its values and priceNo size check
Its AC output is not verified, so we cannot compare it with the limit.
Its values and priceIn order of inverter output, smallest first. We have not tested these kits. The calculator gives its output, savings and payback for your address. For a kit whose seller does not list Vermont for shipping, it gives no payback.